Installation Instructions

Installation Instructions

Information about the Installation Process

INSTALLATION AND SAFETY INSTRUCTIONS READ THESE INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION This fixture is intended for installation in accordance with the National Electric Code(NEC) and Local code specifications. Failure to adhere to these codes and instructions may result in serious injury and/or property damage and will void thewarranty.

  1. WARNING: This fixture is not to be installed within 10 feet (3M) of a pool, spa or fountain.
  2. 2)This fixture is to be used only with a power unit (transformer) rated a maximum of 300 W (25 AMPS) 15 volts.
  3. The #18 ga. fixture wire is not intended for direct burial.
  4. Direct burial rated wire is to be buried a minimum of 6″ (152mm) beneath the surface of the ground.Contact your Tru-ScapesDealer for direct burial wire
  5. Wiring connections must be made with provided wire nuts or other equally suitable connector for the application. Do not exceed manufacturers’ wiring combination specifications for size and quantity of conductors.

CAUTION-WHEN INSTALLING ANY LANDSCAPE LIGHTING (LINE VOLTAGE OR LOW VOLTAGE), CARE SHOULD BE TAKEN TO KEEP CLEAR OF POTENTIALLY COMBUSTIBLE MATERIALS.WHEN MAINTAINING THE FIXTURES, BE SURE TO REMOVE LEAVES, PINE NEEDLES, GRASS CLIPPINGS, MULCH, OR ANY DEBRIS THAT HAS ACCUMULATED ON THE LIGHTBULB, LENS, OR BODY OF THE FIXTURE.

ASSEMBLY AND INSTALLATION Part Numbers TS-B1xx-xxx, TS-B3xx-xxx

  1. TURN OFF POWER.
  2. At desired location, hammer stake (C)into ground. To avoid damage to stake, place a board on top of stake while hammering.
  3. Clear away area in ground at wireway slot (B) in top of stake (A).
  4. Lay 12V cable into wireway slot (B) and screw stem (A) into stake (C). If assembly is not straight, adjust by pushing or pulling on stake only, not the stem.
  5. Make wire connections using supplied wire nuts.

stake-tru-scapes-2024

ASSEMBLY AND INSTALLATION Part Numbers TS-Axxx-xxx, TS-A2xxx-xxx

  1. TURN OFF POWER.
  2. Determine location of each fixture before wall is installed.
  3. DO NOT install in walls where the capstones overhang the wall less than ¾” (19mm)
  4. Insert stainless steel mounting plate between layers of hardscape blocks. Use adhesive or mortar if desired.
  5. Route the fixture wire through the wall to using notches cut into block as needed.6)Make wire connections using supplied wire nuts.

tru-scapes-hardscaping-installation

ASSEMBLY AND INSTALLATION Part Numbers TS-B2xx-xxx Lamp fixture is NOT submersible and adequate drainage must be provided during installation. It is recommended that fixture be surrounded by 3 to 4 inches of pea gravel or sand to assure proper drainage. Top of fixture must remain above grade so rain and irrigation water can not accumulate for a long time

  1. TURN OFF POWER
  2. Dig a hole according to the fixture dimension, allowing 3-4” of pea gravel or sand to surround it.
  3. Make wire connections with supplied wire nuts
  4. Place fixture in hole and backfill with pea gravel or sand.

installation-dasy-chain-lighting-pavers-landscape-tru-scapes